Página 1 - INSTRUCTION MANUAL

Protocol Manager Software E-100 Protocol Manager Network Utility Software INSTRUCTION MANUAL E-100 PN 208711 REVISION H 8/2011

Página 2 - Revision History

Protocol Manager Software E-100 6 Software Setup Configuring the Controllers 1. Use the keys on the faceplate of each Protocol Plus controller

Página 3

Protocol Manager Software E-100 7 Startup and Login 1. Start the application by clicking the Windows taskbar's Start button, then clicking

Página 4 - TABLE OF CONTENTS

Protocol Manager Software E-100 8 Figure 7: User ID after Log in

Página 5 - INTRODUCTION

Protocol Manager Software E-100 9 Setup 1. At this point the system must be set up. Move the cursor to the top of the screen and click on the W

Página 6 - Installing the Software

Protocol Manager Software E-100 10 Comm Setup The first tab on the left is the Comm Setup tab. Use the cursor to make selections to allow the co

Página 7 - Figure 2: License Agreement

Protocol Manager Software E-100 11 Select the baud rate that corresponds to the rate programmed into the Protocol Plus controller(s). 19.2 K is t

Página 8 - Figure 4: Install Screen

Protocol Manager Software E-100 12 Network Setup 1. The second tab from the left on the Software Setup window is the Network tab. Select this t

Página 9

Protocol Manager Software E-100 13 Figure 12: Controller Setup Window Name Field: Designate and type in the name of the oven or controller, up t

Página 10 - Software Setup

Protocol Manager Software E-100 14 Figure 13: Controller Question Popup 4. Click Yes to add the controller to the network.

Página 11 - Startup and Login

Protocol Manager Software E-100 15 Windows Setup 1. The third tab from the left on the Software Setup window is the Windows tab. This allows th

Página 12

Protocol Manager Software E-100 Revision History Revision Date Author Description B Various corrections C Various corrections D Various co

Página 13

Protocol Manager Software E-100 16 2. Click Yes to save settings. Software Setup: Passwords Setup The fourth tab from the left on the Softwar

Página 14 - Comm Setup

Protocol Manager Software E-100 17 Values from 0 minutes to 60 minutes may be set in the Auto Logoff Time window, which will automatically log th

Página 15

Protocol Manager Software E-100 18 Network Summary Window Figure 16: Network Summary Window To view the Network Summary Window, click on the W

Página 16 - Network Setup

Protocol Manager Software E-100 19 Controller Run Time Window Figure 17: Controller Run Time Window The Controller Run Time Window displays cu

Página 17

Protocol Manager Software E-100 20 Network Summary window does not appear in the main menu, click on windows on the task bar and then click on Ne

Página 18

Protocol Manager Software E-100 21 Figure 19: Expanded Controller Run Time Window with Datalogs not enabled The expanded window appears as show

Página 19 - Windows Setup

Protocol Manager Software E-100 22 Configuring a Recipe To create a recipe, go to the bar at the top of the screen and pull down to Recipe/ Data

Página 20

Protocol Manager Software E-100 23 Double-click on the fields in the center of the Recipe/Datalog window to bring up a window box to access and c

Página 21

Protocol Manager Software E-100 24 EV1 through 4 From 1 to 4 events may be programmed into the soak portion of each segment here. These typically

Página 22

Protocol Manager Software E-100 25 Figure 23: MODBUS Comm Error Message Note on Standby Mode In the recipe editor screen, the Link to Profile

Página 23

Protocol Manager Software E-100 Thank you for choosing Despatch Industries. We appreciate the opportunity to work with you and to meet your

Página 24

Protocol Manager Software E-100 26 3. Enter the values desired. 4. Press SAVE to save the recipe. Opening an Existing Recipe 1. Press the O

Página 25

Protocol Manager Software E-100 27 Reading/Writing a Recipe to/from a Controller 1. Select the controller from the box at the bottom right corn

Página 26 - Configuring a Recipe

Protocol Manager Software E-100 28 Recipe Selection Setup 1. Go to the second tab from the left at the top of the Recipe Editor screen. 2. Cl

Página 27

Protocol Manager Software E-100 29 the "Selectable Recipe Files" list that will be displayed in the controller start window (see "

Página 28

Protocol Manager Software E-100 30 Datalog Functions Datalog files are maintained to periodically record controller data to a disk file for futu

Página 29 - Creating a New Recipe

Protocol Manager Software E-100 31 The Profile Datalog and Lot Datalog screens are accessed from the tabs at the right side of the initial Recipe

Página 30 - Opening an Existing Recipe

Protocol Manager Software E-100 32 Log File Record Data Check the following boxes to select the types of data to be written into the log file i

Página 31

Protocol Manager Software E-100 33 Log File Naming Options Log file names consist of a Controller ID and Time Stamp, created when a data log is

Página 32 - Recipe Selection Setup

Protocol Manager Software E-100 34 Figure 28: Lot Datalog Window The Lot Datalog screen enables datalog functions to be selected on a per-job ba

Página 33

Protocol Manager Software E-100 35 STARTING THE CONTROLLER The controller is started by using the Controller Run Time Window(s) which are access

Página 34 - Datalog Functions

Protocol Manager Software E-100 i TABLE OF CONTENTS INTRODUCTION ...

Página 35 - Log File Header Information

Protocol Manager Software E-100 36 Run Time Window Three different modes of operation are available as tabs from the Start Running screen: Man

Página 36 - Log File Record Data

Protocol Manager Software E-100 37 Timer Mode Figure 31 illustrates Timer Mode. This mode allows the operator to start and stop the process for

Página 37 - Log File Naming Options

Protocol Manager Software E-100 38 Profile Mode Figure 32 illustrates Profile Startup Mode with the "Start Profile by Number" option s

Página 38

Protocol Manager Software E-100 39 Figure 33 illustrates Profile Mode startup with the “Start Profile by Recipe Name” option selected (see “Recip

Página 39 - STARTING THE CONTROLLER

Protocol Manager Software E-100 40 COMMUNICATION CARD INSTALLATION AND JUMPER SETTINGS Wiring Diagrams Figure 34: RS232 Wiring Figure 35: RS

Página 40 - Run Time Window

Protocol Manager Software E-100 41 Communication Card Installation 1. Turn off power to the controller. 2. Remove the back cover of the con

Página 41 - Timer Mode

Protocol Manager Software E-100 42 Figure 37: Controller rear view with Communications Card (left)

Página 42 - Profile Mode

Protocol Manager Software E-100 43 Communication Card Jumper Settings 1. Turn off power to the controller. 2. Remove the back cover of the co

Página 43

Protocol Manager Software E-100 44 Connecting Protocol Plus Controller(s) to a Communications Host PC Single Oven If the oven purchased was no

Página 44 - Wiring Diagrams

Protocol Manager Software E-100 45 network ports; “Communication In” and “Communication Out”. For shorter networking runs, standard serial commu

Página 45

Protocol Manager Software E-100 1 INTRODUCTION The Despatch Protocol Manager network utility software enables the operation of multiple Protocol

Página 46

Protocol Manager Software E-100 46 Figure 39: Junction Box Wiring

Página 47

Protocol Manager Software E-100 47 The junction boxes are used to provide a drop from the network cable to each Oven. The cables marked "To

Página 48 - Multiple Ovens

Protocol Manager Software E-100 48 TROUBLESHOOTING THE COMMUNICATIONS OPTION Controller Parameters (see Protocol Plus manual to enter Communica

Página 49

Protocol Manager Software E-100 49 5. Click on the Network tab and highlight the oven you are trying to setup. Click on the Edit button.

Página 50

Protocol Manager Software E-100 50 6. Make sure the address matches and the password is set to the level 2 password of the controller (Default

Página 51

Protocol Manager Software E-100 51 Controller Hardware and Cabling Check the communications card The card needs to be installed correctly (ju

Página 52 - COMMUNICATIONS OPTION

Protocol Manager Software E-100 52 Despatch kit p/n 161968 includes all parts required to make one oven communication-ready. The kit also contai

Página 53

Protocol Manager Software E-100 53

Página 54

Protocol Manager Software E-100 2 INSTALLATION Host Computer Requirements The host computer must be Pentium-class or equivalent, running Window

Página 55

Protocol Manager Software E-100 3 6. Click on the Next button. The following screen will appear: Figure 2: License Agreement 7. Scroll the w

Página 56

Protocol Manager Software E-100 4 8. The following Destination Folder screen will appear. Figure 3: Destination Folder Selection 9. Either

Página 57

Protocol Manager Software E-100 5 10. If all is in order, click the Install button to install the software. When the installation is complete, th